Cardiac segmentation for ventricular tachycardia radioablation and radiotherapy patients with cardiac implants
Nicholas Summerfield, Dustin Jacqmin, Chase Ruff, Andrew M. Baschnagel, Adam Burr, Michael Bassetti, Ryan Kipp, Matthew Kalscheur, Patrick M. Hill, Ming Dong, Carri Glide-Hurst
Abstract
Deep-learning (DL) segmentation enables cardiac substructure (CS) delineation for advanced cardiac-sparing radiation therapy (RT). Patients presenting for RT may have implantable devices (cardioverter-defibrillators (ICDs)) and metal artifacts. Stereotactic body RT (SBRT) is used to treat ventricular tachycardia (VT), a population frequently with ICDs. We apply a DL model for RT patients with ICDs or undergoing VT-SBRT, enabling segmentation and CS-level dose analysis. CT simulation (CT-SIM) of 19 patients with ICDs and received VT-SBRT were evaluated. A validated segmentation model was retrained using a highly-curated CT-SIM cohort, supplemented with ICD images for training and validation, with a hold-out ICD test set (n=10), to predict 20 CS. Additional CT-SIM datasets included cancer-RT patients with (n=9) and without (n=10) ICDs to evaluate generalizability. The retrained ICD-supplemented model was compared against a non-ICD model using Dice similarity coefficient (DSC), 95% Hausdorff distance (HD95), and Wilcoxon signed-rank test (p<0.05). Dosimetric evaluation was performed for VT-SBRT CS. For VT-SBRT, the ICD-supplemented model achieved average DSC/HD95 of 0.71(0.19)/10.7(22.5)mm respectively, outperforming (p<0.05) the non-ICD model. On CT-SIM with ICDs, average DSC/HD95 were 0.70(0.22)/7.9(5.1)mm respectively, outperforming (p<0.05) the non-ICD model. On CT-SIM without ICDs, the average DSC was 0.74(0.17) (Non-ICD, DSC, 0.75(0.16), p<0.05) and average HD95 was 5.5(3.1)mm (Non-ICD, HD95, 5.3(2.8mm)). For VT-SBRT, CS dose depended on target location, with higher relative dose delivered to the ventricles, tricuspid valve, atrioventricular node, and left coronary arteries than other CS. ICD-supplemented training improved CS segmentation despite metal artifacts without meaningfully degrading non-ICD performance, supporting segmentation and CS-level dosimetry in ICD populations.
Create a lesson
Related papers
Quantifying the Impact of Upright Patient Positioning on Cardiac Substructures Using Deep Learning
Shared title terminology · Nicholas Summerfield, Yuhao Yan, Chase Ruff et al.
Towards Modeling the Hemodynamic Impact of Mitral and Aortic Valve Repair in Patients with Left Ventricular Assist Devices
Shared title terminology · Mia Bonini, Michael Ferguson, Marc Hirshvogel et al.
MRI-guided cardiac radiotherapy using a 1.5 T MR-linac: surveying emerging patterns of care
Shared title terminology · O. Akdag, S. Mandija, J. Pomp et al.
MRI-Driven Dual-Energy CT Synthesis via Conditional Denoising Diffusion Probabilistic Models for MRI-only Radiotherapy and Protontherapy
Shared title terminology · Juan Manuel Molina-Maza Chih-Wei Chang, David Viar-Hernandez, Zach Eidex et al.
Towards consensus on practical probabilistic evaluation metrics for clinical decision making in radiotherapy
Shared title terminology · Jenneke I. de Jong, Steven J. M. Habraken, Erik W. Korevaar et al.
A High-Fidelity Cardiac Digital Twin for Assessing Rate-Dependent Responses: A Comparative Multi-scale Study of TT2 and Tomek Models in Stratified 3D Ventricles
Shared title terminology · Zhenyin Fu, Zhaokai Kong, Lucheng Xu et al.