Development and Performance Study of a Capillary Liquid Scintillator Neutron Detector
Guang Luo, Jian Yu, Dikai Li, Yanmeng Dai, Meiling Chen, Jiaqiang Zou, Ke Yan, Shaoxuan Cui, Ge Jin, Zhao Xu, Chunhui Zhang, Leifeng Cao
Abstract
Capillary liquid scintillator detectors are promising for high-resolution neutron imaging, yet experimental data on their light spread mechanism and spatial performance remain limited. Here, we report a neutron detector based on a hexagonal capillary array filled with EJ-309 liquid scintillator, with an inner diameter of about 50 um and a camera readout of 9 um pixels. Laser experiments show that the FWHM of the full light spot decreases from 260 um to 90 um with a metal light absorber, confirming effective suppression of lateral light spread. Using an AmBe neutron source, an effective field of view with a 5-sigma threshold was established from background frames. For single-capillary events, the pulse height spectrum follows a Landau distribution with a most probable value of 0.133 +/- 0.001 (stat.), and the intrinsic detection efficiency is 10.07% +/- 1.26% (stat.) +/- 1.43% (syst.), corresponding to about 13.55% when normalized to the active liquid scintillator area. The point spread function core yields a radial FWHM of 12.8 um and a centroid positioning precision of approximately 5.5 um (1 sigma), while the intrinsic position resolution is limited by the capillary pitch to 54 um. Linearity is good for 1 to 2 capillaries, with deviation appearing for 2 to 3 capillaries due to additional capture of spread light. These results provide experimental basis and physical understanding for imaging applications of capillary liquid scintillator neutron detectors.
Create a lesson
Related papers
State of the Art in Direct Dark Matter Detectors: Technologies, Performance, and Future Directions
Muad Ghaith, Khaled Obaideen
Impact of Gain Layer Doping Concentration on the Performance of 4H-SiC LGADs
Tao Yang, Ben J. Sekely, Yashas Satapathy et al.
Performance and quality testing of CBM RICH front-end electronics
Pavish Subramani, Christian Pauly, Joerg Foertsch et al.
Measurement of the 39Ar specific activity in atmospheric argon with DArT at the Canfranc Underground Laboratory
P. Agnes, H. O. Back, S. Bharat et al.
Kilopixel Performance of the Kinetic Inductance Detectors for the Terahertz Intensity Mapper
Justin S. Bracks, Reinier M. J. Janssen, Steve Hailey-Dunsheath et al.
Quantitative Interleaved-Pulse Acquisition Extends the Range of Isotope-Ratio Measurements in ToF-SIMS
Anton V. Ievlev