Measurement of the 39Ar specific activity in atmospheric argon with DArT at the Canfranc Underground Laboratory
P. Agnes, H. O. Back, S. Bharat, W. M. Bonivento, M. Boulay, M. Caboni, N. Canci, N. Cargioli, P. Castello, S. Cebrián, L. Consiglio, R. Crampton, D. Diaz Mairena, D. Franco, I. Fuente-Ortega, F. Gabriele, D. Gahan, C. Galbiati, P. Garcia Abia, T. Hessel, S. Horikawa, A. Ianni, G. Korga, M. Kuźniak, L. Luzzi, A. Marasciulli, M. Martínez, P. Organtini, A. Ortiz de Solórzano, R. Pavarani, P. Pegoraro, V. Pesudo Fortes, M. Razeti, O. U. Rehman, L. Romero, D. Sablone, E. Sánchez García, R. Santorelli, C. Seoane, J. Sosiak, S. Sulis, C. Tierney, S. Tullio, G. Vera Díaz
Abstract
We report the measurement of the 39Ar specific activity of atmospheric argon using DArT, a low-background single-phase liquid-argon detector read out by cryogenic silicon photomultipliers, at the Canfranc Underground Laboratory (LSC) in Spain. DArT was first filled with atmospheric argon and then with a sample of underground argon of known radioactivity from the DarkSide-50 experiment. The underground argon serves as a background reference in this measurement, making the result robust because we do not rely on background simulations. We measure the 39Ar specific activity with both a cut-and-count method and a binned maximum-likelihood fit, yielding consistent results. We obtain aAAr= 0.955 0.008~Bq/kg. This result agrees with previous measurements from other experiments and provides the most precise determination of the 39Ar specific activity in atmospheric argon to date. It also validates DArT as a key component of the DArTInArDM experiment at LSC, which aims to measure the 39Ar activity of the argon extracted from deep underground wells in Colorado (USA) for the Darkside-20k and LEGEND-1000 experiments at Laboratori Nazionali del Gran Sasso in Italy.
Create a lesson
Related papers
State of the Art in Direct Dark Matter Detectors: Technologies, Performance, and Future Directions
Muad Ghaith, Khaled Obaideen
Impact of Gain Layer Doping Concentration on the Performance of 4H-SiC LGADs
Tao Yang, Ben J. Sekely, Yashas Satapathy et al.
Performance and quality testing of CBM RICH front-end electronics
Pavish Subramani, Christian Pauly, Joerg Foertsch et al.
Kilopixel Performance of the Kinetic Inductance Detectors for the Terahertz Intensity Mapper
Justin S. Bracks, Reinier M. J. Janssen, Steve Hailey-Dunsheath et al.
Quantitative Interleaved-Pulse Acquisition Extends the Range of Isotope-Ratio Measurements in ToF-SIMS
Anton V. Ievlev
Development and Performance Study of a Capillary Liquid Scintillator Neutron Detector
Guang Luo, Jian Yu, Dikai Li et al.