Direct reading of charge multipliers with a self-triggering CMOS analog chip with 105k pixels at 50 micron pitch
R. Bellazzini, G. Spandre, M. Minuti, L. Baldini, A. Brez, F. Cavalca, L. Latronico, N. Omodei, M. M. Massai, C. Sgro, E. Costa, P. Soffitta F. Krummenacher, R. DeOliveira
Abstract
We report on a large active area (15x15mm2), high channel density (470 pixels/mm2), self-triggering CMOS analog chip that we have developed as pixelized charge collecting electrode of a Micropattern Gas Detector. This device, which represents a big step forward both in terms of size and performance, is the last version of three generations of custom ASICs of increasing complexity. The CMOS pixel array has the top metal layer patterned in a matrix of 105600 hexagonal pixels at 50 micron pitch. Each pixel is directly connected to the underneath full electronics chain which has been realized in the remaining five metal and two poly-silicon layers of a 0.18 micron VLSI technology. The chip has customizable self-triggering capability and includes a signal pre-processing function for the automatic localization of the event coordinates. In this way it is possible to reduce significantly the readout time and the data volume by limiting the signal output only to those pixels belonging to the region of interest. The very small pixel area and the use of a deep sub-micron CMOS technology has brought the noise down to 50 electrons ENC. Results from in depth tests of this device when coupled to a fine pitch (50 micron on a triangular pattern) Gas Electron Multiplier are presented. The matching of readout and gas amplification pitch allows to get optimal results. The application of this detector for Astronomical X-Ray Polarimetry is discussed. The experimental detector response to polarized and unpolarized X-ray radiation when working with two gas mixtures and two different photon energies is shown. Results from a full MonteCarlo simulation for several galactic and extragalactic atronomical sources are also reported.
Create a lesson
Related papers
Design and performance of the Fast Beam Condition Monitor for luminosity and background measurement at the CMS Experiment in LHC Run 3
The CMS BRIL Collaboration, Eliana Acurio, Ying An et al.
AlGaN/GaN Hall-Effect Sensor for In-Situ Magnetic Field Monitoring of the HSX Stellarator
Yiming Zhao, Wayne Goodman, Thomas Gallenberger et al.
Measuring and Modelling Lag in Amorphous Silicon Flat-Panel X-ray Detectors
Yiyue Huang, Benjamin Young, Andrew Kingston et al.
Signal formation and induction-gap optimization in a THGEM coupled to a resistive plate anode
Arpan Maity, Luca Moleri, Maryna Borysova et al.
Development and Commissioning of the Cryogenic Target Detectors for the Technical Run of the NUCLEUS Experiment
N. Schermer, H. Abele, G. Angloher et al.
Aliased noise characterization and mitigation in BICEP Array 150, 220 and 270 GHz time-division multiplexed detectors
S. Fatigoni, P. A. R. Ade, Z. Ahmed et al.