FIRST: Fast Iterative Reconstruction Software for (PET) tomography
J. L. Herraiz, S. Espana, J. J. Vaquero, M. Desco, J. M. Udias
Abstract
Small animal PET scanners require high spatial resolution and good sensitivity. To reconstruct high-resolution images in 3D-PET, iterative methods, such as OSEM, are superior to analytical reconstruction algorithms, although their high computational cost is still a serious drawback. The higher performance of modern computers could make iterative image reconstruction fast enough to be viable, provided we are able to deal with the large number of probability coefficients for the system response matrix in high-resolution PET scanners, which is a difficult task that prevents the algorithms from reaching peak computing performance. Considering all possible axial and in-plane symmetries, as well as certain quasi-symmetries, we have been able to reduce the memory requirements to store the system response matrix (SRM) well below 1 GB, which allows us to keep the whole response matrix of the system inside RAM of ordinary industry-standard computers, so that the reconstruction algorithm can achieve near peak performance. The elements of the SRM are stored as cubic spline profiles and matched to voxel size during reconstruction. In this way, the advantages of on-the-fly calculation and of fully stored SRM are combined. The on-the-fly part of the calculation (matching the profile functions to voxel size) of the SRM accounts for 10 to 30% of the reconstruction time, depending on the number of voxels chosen. We tested our approach with real data from a commercial small animal PET scanner. The results (image quality and reconstruction time) show that the proposed technique is a feasible solution.
Create a lesson
Related papers
Constrained estimation of rotational invariants of the cumulant expansion (RICE) for rapid tensor-valued diffusion MRI
Jinyang Yu, Oliver Gödicke, Frederik B. Laun et al.
Dose-PlanNet: Physics Based Radiotherapy Dose Prediction with Deep Learning
Ankit Bhattacharjee, Sougata Maity, Santam Chakraborty et al.
Sparse Delta Integration method for the calculation of spatiotemporal pressure fields of arbitrary ultrasound transducer geometries
Deyver E. Rivera, Charlie Demene, Mickael Tanter
Adapting the TG-43 formalism for use in Diffusing alpha-emitters Radiation Therapy
Guy Heger, Lior Epstein, Lior Arazi
Evaluation of the Exradin A30 Parallel Plate Ion Chamber as a Reference Dosimeter in Ultra-High Dose Rate (UHDR) Electron Beams
Mervat Alharbi, Kevin Liu, Brian Hooten et al.
Clustering of anterior corneal surface shapes in normal adults
Hala Bouazizi, Isabelle Brunette, Jean Meunier