Development and Commissioning of the Cryogenic Target Detectors for the Technical Run of the NUCLEUS Experiment
N. Schermer, H. Abele, G. Angloher, B. Arnold, M. Atzori Corona, A. Bento, E. Bossio, F. Buchsteiner, J. Burkhart, F. Cappella, M. Cappelli, N. Casali, R. Cerulli, A. Cruciani, G. Del Castello, S. Dorer, A. Erhart, M. Friedl, S. Fichtinger, V. M. Ghete, M. Giammei, J. Hakenmüller, D. Hauff, M. Hock, F. Jeanneau, E. Jericha, M. Kaznacheeva, H. Kluck, A. Langenkämper, T. Lasserre, D. Lhuillier, M. Mancuso, B. Mauri, A. Mazzolari, L. McCallin, H. Neyrial, C. Nones, L. Oberauer, L. Peters, F. Petricca, W. Potzel, F. Pröbst, F. Reindl, M. Romagnoni, J. Rothe, J. Schieck, S. Schönert, C. Schwertner, L. Scola, L. Stodolsky, A. Schröder, R. Strauss, R. Thalmeier, C. Tomei, L. Valla, M. Vignati, M. Vivier, A. Wallach, P. Wasser, L. Wienke
Abstract
The NUCLEUS experiment aims to study coherent elastic neutrino-nucleus scattering (CEνNS) of reactor electron antineutrinos at the Chooz nuclear power plant in France. In this work, the cryogenic target-detector module for the NUCLEUS Technical Run was developed and commissioned at the Technical University of Munich. The module comprises four gram-scale CaWO4 detectors, each equipped with two Transition Edge Sensors (TES), providing a total target mass of 6.96 g. We present the design, integration, detector characterization, and X-ray-based energy calibration of these detectors. Across six characterized detectors, a mean baseline resolution of σBL = (2.79 0.60)\,eV was achieved. The best-performing detector reached σBL = (2.16 0.02stat)\,eV, surpassing the design goal by a factor of two and representing a state-of-the-art result for a cryogenic CaWO4 detector. The target detector module was successfully operated simultaneously with the surrounding Cryogenic Outer Veto, which consists of six kg-scale Ge detectors for background discrimination, showing no measurable cross-talk. These results demonstrate the readiness of the target-detector system for the NUCLEUS Technical Run at Chooz and mark a key milestone in the development of cryogenic detectors for reactor-CEνNS measurements.
Create a lesson
Related papers
Design and performance of the Fast Beam Condition Monitor for luminosity and background measurement at the CMS Experiment in LHC Run 3
The CMS BRIL Collaboration, Eliana Acurio, Ying An et al.
AlGaN/GaN Hall-Effect Sensor for In-Situ Magnetic Field Monitoring of the HSX Stellarator
Yiming Zhao, Wayne Goodman, Thomas Gallenberger et al.
Measuring and Modelling Lag in Amorphous Silicon Flat-Panel X-ray Detectors
Yiyue Huang, Benjamin Young, Andrew Kingston et al.
Signal formation and induction-gap optimization in a THGEM coupled to a resistive plate anode
Arpan Maity, Luca Moleri, Maryna Borysova et al.
Aliased noise characterization and mitigation in BICEP Array 150, 220 and 270 GHz time-division multiplexed detectors
S. Fatigoni, P. A. R. Ade, Z. Ahmed et al.
Fabrication and validation of a MEMS Electron Monochromator
M. J. Adriaans, J. P. Hoogenboom, A. Mohammadi-Gheidari