The liquid-phase xenon purification system of the XENONnT dark matter experiment
E. Aprile, J. Aalbers, K. Abe, M. Abu Rmilah, M. Adrover, S. Ahmed Maouloud, L. Althueser, B. Andrieu, E. Angelino, D. Antón Martin, S. R. Armbruster, F. Arneodo, L. Baudis, M. Bazyk, V. Beligotti, L. Bellagamba, R. Biondi, K. Boese, R. M. Braun, G. Bruni, R. Budnik, C. Cai, C. Capelli, J. M. R. Cardoso, A. P. Cimental Chávez, A. P. Colijn, J. Conrad, J. J. Cuenca-García, H. Dai, V. D'Andrea, L. C. Daniel Garcia, M. P. Decowski, A. Deisting, C. Di Donato, P. Di Gangi, S. Diglio, K. Eitel, S. el Morabit, R. Elleboro, A. Elykov, A. D. Ferella, C. Ferrari, H. Fischer, T. Flehmke, M. Flierman, R. Frankel, D. Fuchs, W. Fulgione, C. Fuselli, F. Gao, R. Giacomobono, R. Glade-Beucke, L. Grandi, J. Grigat, A. Guerrero Ramos, M. Guida, P. Gyorgy, R. Hammann, C. Hils, L. Hoetzsch, N. F. Hood, J. Howlett, J. Huang, A. Hurhina, M. Iacovacci, Y. Itow, J. Jakob, F. Joerg, Y. Kaminaga, S. Kazama, P. Kharbanda, M. Kobayashi, D. Koke, N. Kato, K. Kooshkjalali, A. Kopec, E. Kozlova, H. Landsman, L. Levinson, A. Li, H. Li, I. Li, J. Li, K. Li, S. Li, S. Y. Li, Z. Liang, Y. -T. Lin, S. Lindemann, M. Lindner, K. Liu, M. Liu, F. Lombardi, J. A. M. Lopes, G. M. Lucchetti, T. Luce, Y. Ma, C. Macolino, G. C. Madduri, J. Mahlstedt, F. Marignetti, T. Marrodán Undagoitia, K. Martens, J. Masbou, S. Mastroianni, V. Mazza, J. Merz, M. Messina, A. Michel, K. Miuchi, R. Miyata, A. Molinario, S. Moriyama, M. Murra, J. Müller, K. Ni, C. T. Oba Ishikawa, U. Oberlack, K. Otsuzuki, S. Ouahada, B. Paetsch, J. Palacio, Y. Pan, Q. Pellegrini, J. Pienaar, M. Pierre, G. Plante, T. R. Pollmann, F. Pompa, A. Prajapati, L. Principe, J. Qin, A. Ravindran, A. Razeto, L. Sanchez, J. M. F. dos Santos, I. Sarnoff, G. Sartorelli, M. T. Schiller, P. Schulte, H. Schulze Eißing, M. Schumann, L. Scotto Lavina, M. Selvi, F. Semeria, F. N. Semler, P. Shagin, X. Shen, S. Shi, H. Simgen, Z. Song, A. Stevens, C. Szyszka, A. Takeda, Y. Takeuchi, P. -L. Tan, D. Thers, G. Trinchero, C. D. Tunnell, K. Valerius, S. Vecchi, S. Vetter, G. Volta, B. von Krosigk, C. Weinheimer, M. Weiss, D. Wenz, C. Wittweg, V. H. S. Wu, Y. Xing, D. Xu, Z. Xu, M. Yamashita, J. Yang, L. Yang, J. Ye, M. Yoshida, G. Zavattini, Y. Zhao, M. Zhong, T. Zhu
Abstract
The XENONnT dark matter experiment utilizes a dual-phase time projection chamber (TPC) housed in a cryostat filled with 8.5 t of ultra-pure liquid xenon. To achieve optimal sensitivity, free electrons generated by particle interactions are required to drift across the 1.5-meter detector under an electric field. Dissolved impurities, particularly oxygen (O), can attenuate the resulting charge signal due to electron attachment. XENONnT demands an O-equivalent concentration below 100 parts per trillion (ppt) to enable its dark matter sensitivity reach. A novel liquid-phase xenon purification system was developed that continuously circulates liquid xenon through custom-designed, packed-bed sorbent purifier units at a volumetric flow rate of 2 liters per minute (L/min) at a cryogenic temperature around 175 K. With a purification time constant of approximately 25 h, the system reached the required purity within five days. The purification strategy employs a two-step approach: For an initial cleanup, a purifier based on a copper catalyst on high-surface-area alumina support (Q5) removes impurities from the liquid xenon bulk with nearly 100% efficiency, ideal for initial detector filling or after long-term maintenance. However, the high Rn emanation rate of the Q5 catalyst leads to increased background in the detector. In a second step, a purifier with sintered pellets of non-evaporable getter alloy (St707) ensures sustained purity with negligible background impact. The St707-based purifier exhibits a 55% efficiency, sufficient for normal operation. Following system commissioning, XENONnT achieved an O-equivalent concentration in liquid xenon below 19 ppt during its first science run. With this exceptional purity, over 86% of generated electrons survive a full drift across the TPC.
Create a lesson
Related papers
Cryogenic characterisation of the FBK NUV-HD-cryo Silicon Photomultipliers for the DarkSide-20k dark matter experiment
Shared title terminology · F. Acerbi, P. Adhikari, P. Agnes et al.
Investigating Optical Coupling Material Candidates in NaI(Tl) Detectors for the SABRE-North Dark Matter Experiment
Shared title terminology · Chemseddine Ananna, Gabriella Cataldi, Davide D'Angelo et al.
Evaluation of tracking plane pitch and xenon-helium gas mixtures for the NEXT experiment
Shared title terminology · NEXT Collaboration, M. Pérez Maneiro, M. Cid et al.
First demonstration of long-distance electron drift in liquid xenon with the Xenoscope time projection chamber
Shared title terminology · N. Angelides, M. Babicz, E. E. Barillier et al.
CMS ECAL Phase-2 upgrade: characterisation and stability analysis of a three-stage low-voltage power-conversion system
Shared title terminology · Liv Anke Richter, Günther Dissertori, Werner Lustermann et al.
Construction and Commissioning of a Compact Xenon Gas Recycling System for a High-Harmonic Generation VUV Frequency Comb
Shared title terminology · G. Holthoff, J. Rebhan, T. Teuner et al.