Dark Matter Sensitivity of the CYGNO Detector with HFO-1234ze Enhanced Gas Mixtures
F. D. Amaro, R. Antonietti, E. Baracchini, L. Benussi, F. M. Brunbauer, C. Capoccia, M. Caponero, L. G. M. de Carvalho, G. Cavoto, I. A. Costa, A. Croce, M. D'Astolfo, G. D'Imperio, E. Dane', G. Dho, E. Di Marco, J. M. F. dos Santos, D. Fiorina, F. Iacoangeli, Z. Islam, E. Kemp, H. P. Lima, G. Maccarrone, R. D. P. Mano, D. J. G. Marques, G. Mazzitelli, P. Meloni, A. Messina, C. M. B. Monteiro, R. A. Nobrega, E. Olivieri, I. F. Pains, E. Paoletti, F. Petrucci, S. Piacentini, D. Pierluigi, D. Pinci, F. Renga, A. Russo, G. Saviano, P. A. O. C. Silva, N. J. Spooner, R. Tesauro, S. Tomassini, D. Tozzi
Abstract
The CYGNO collaboration introduces an innovative approach to direct dark matter detection, proposing a high-resolution optical Time Projection Chamber. It operates at atmospheric pressure with a He:CF4 (60:40) gas mixture and uses a triple Gas Electron Multiplier stage for signal amplification. A key feature is its optical readout system, which captures the scintillation light produced during the electron avalanche. This setup allows 3D event reconstruction by combining the time profile of the light detected by photomultiplier tubes with high-granularity, pixelated X-Y tracking recorded by a scientific camera. The CYGNO experiment's projected sensitivity to both spin-independent and spin-dependent interactions is competitive in the framework of directional dark matter detectors. However, incorporating a hydrogen-based gas would introduce an even lighter target, further improving the detection potential at low dark matter masses. In this work, we present the performance characterization of one of the CYGNO experiment prototypes, MANGO, operated with the standard gas mixture enriched with varying concentrations of HFO-1234ze, a gas with a promising low global warming potential. The study includes measurements of the detector charge gain and scintillation yield for each configuration. In addition, to evaluate the impact of HFO-1234ze on scintillation light quenching, the secondary scintillation spectrum was collected for each gas mixture tested.
Create a lesson
Related papers
Design and performance of the Fast Beam Condition Monitor for luminosity and background measurement at the CMS Experiment in LHC Run 3
The CMS BRIL Collaboration, Eliana Acurio, Ying An et al.
AlGaN/GaN Hall-Effect Sensor for In-Situ Magnetic Field Monitoring of the HSX Stellarator
Yiming Zhao, Wayne Goodman, Thomas Gallenberger et al.
Measuring and Modelling Lag in Amorphous Silicon Flat-Panel X-ray Detectors
Yiyue Huang, Benjamin Young, Andrew Kingston et al.
Signal formation and induction-gap optimization in a THGEM coupled to a resistive plate anode
Arpan Maity, Luca Moleri, Maryna Borysova et al.
Development and Commissioning of the Cryogenic Target Detectors for the Technical Run of the NUCLEUS Experiment
N. Schermer, H. Abele, G. Angloher et al.
Aliased noise characterization and mitigation in BICEP Array 150, 220 and 270 GHz time-division multiplexed detectors
S. Fatigoni, P. A. R. Ade, Z. Ahmed et al.