Cracking under pressure --- investigating mitigation approaches for silicon fractures on ATLAS strip tracker petals at cold temperatures
S. H. Abidi, J. -H. Arling, M. J. Basso, S. Beaupre, I. Bloch, A. J. Blue, M. Caspar, J. Chen, S. Díez Cornell, U. Epstein, E. K. Filmer, A. Fournier, L. Franconi, A. Gabrielli, J. A. Hallford, S. Heim, C. M. Helling, N. P. Hessey, R. M. Jacobs, T. Kuhl, M. Licht, C. K. Mahajan, S. Manson, K. Mauer, S. Oerdek, V. Platero Montagut, L. Poley, C. O. Sander, K. Ran, S. Sinha, C. Solaz Contell, U. Soldevila Serrano, D. Sperlich, B. Stelzer, A. H. Tigchelaar, E. Torres Reoyo, G. Vallone, L. M. Veloce
Abstract
For the High-Luminosity upgrade of the Large Hadron Collider, the ATLAS experiment will replace its current Inner Detector with an all-silicon Inner Tracker (ITk), consisting of pixel and strip detectors. The strip detector will consist of a central region or "barrel" assembled with staves and forward regions or "end-caps" assembled with petals. The ITk will nominally operate with liquid CO2 cooling at -35\,C; however, in the event of cooling system failures, it is possible that sensors will experience temperatures below -35\,C. At these low temperatures, it has been observed that the silicon sensors within modules --- the fundamental readout units of the detector --- can physically crack, rendering the modules inoperable. Understanding and resolving the issue of sensor cracking was one of the most important and urgent issues for the ITk project. This paper presents part of the mitigation strategies developed for petals. These mitigation strategies are based on modifications to the choice of adhesive and its deposition pattern for module assembly and petal loading. The most promising mitigation strategy presented here prevents cracking to temperatures as low as -45\,C, which can be expected in case of cooling system problems, with a small percentage of cracks observed after being cycled to -55\,C, which can be expected in case of catastrophic cooling system failures.
Create a lesson
Related papers
Design and performance of the Fast Beam Condition Monitor for luminosity and background measurement at the CMS Experiment in LHC Run 3
The CMS BRIL Collaboration, Eliana Acurio, Ying An et al.
AlGaN/GaN Hall-Effect Sensor for In-Situ Magnetic Field Monitoring of the HSX Stellarator
Yiming Zhao, Wayne Goodman, Thomas Gallenberger et al.
Measuring and Modelling Lag in Amorphous Silicon Flat-Panel X-ray Detectors
Yiyue Huang, Benjamin Young, Andrew Kingston et al.
Signal formation and induction-gap optimization in a THGEM coupled to a resistive plate anode
Arpan Maity, Luca Moleri, Maryna Borysova et al.
Development and Commissioning of the Cryogenic Target Detectors for the Technical Run of the NUCLEUS Experiment
N. Schermer, H. Abele, G. Angloher et al.
Aliased noise characterization and mitigation in BICEP Array 150, 220 and 270 GHz time-division multiplexed detectors
S. Fatigoni, P. A. R. Ade, Z. Ahmed et al.