Beam test results of the irradiated Silicon Drift Detector for ALICE
S. Kushpil, E. Crescio, P. Giubellino, M. Idzik, A. Kolozhvari, V. Kushpil, M. I. Martinez, G. Mazza, A. Mazzoni, F. Meddi, D. Nouais, V. Petracek, C. Piemonte, A. Rashevsky, L. Riccati, A. Rivetti, F. Tosello, A. Vacchi, R. Wheadon
Abstract
The Silicon Drift Detectors will equip two of the six cylindrical layers of high precision position sensitive detectors in the ITS of the ALICE experiment at LHC. In this paper we report the beam test results of a SDD irradiated with 1 GeV electrons. The aim of this test was to verify the radiation tolerance of the device under an electron fluence equivalent to twice particle fluence expected during 10 years of ALICE operation.